The extruded motor housing is applied to the motor housing and has a good heat dissipation function.
Extruded motor housings are used in: micro motor housings, environmentally friendly air conditioner motor housings, air cooler motor housings, water-cooled air conditioner motor housings, air compressor motor housings, negative pressure fans, motor housings, electric vehicle motor housings, tricycle motor housings, servo motors Special housing, injection molding machine motor, cooling tower motor, cylinder barrel, axial fan motor, power tool motor, geared motor, etc.
The extruded motor housing has the advantages of light weight, high strength, good heat dissipation performance, beautiful and generous surface, and free cutting of the inner bore.
Reasons for electrification of extruded motor housing:
1. The cause of the failure may be:
1) The motor winding is damp or the insulation is seriously aging;
2) Poor grounding;
3) The power line and the grounding line are wrong;
4) The wiring board is dirty;
5) The insulation of the lead wire is aging and damaged;
6) The winding end cover is grounded.
2. The corresponding processing methods are:
1) Dry the damp motor; the aging insulation must be renewed in time.
2) Find out the cause along the ground wire and take corresponding measures to correct it.
3) Correct the wiring error after finding the power line and grounding line.
4) Clean the wiring board.
5) Wrap up or new lead wires with insulating tape.
6) Remove the end cover and find the grounding point. The grounding point of the coil should be wrapped, insulated and painted, and the inner wall of the end cover should be lined with insulating paper.